Contact an Account ManagerDetermination of bisphenol A in water
Summary
Type: SPE
Application #: 303211
Catalog#: 730108 - SPE Cartridges, Chromabond, HR-P, 3ml, PP, 200mg 30/pk
Detection: GC
Conditions: Conditioning: with 3 ml Methanol
Sample application: 250 ml sample are applied with 15 ml/min
Equilibration: with 3 ml dest. Water
Washing: with dest. Water pH 2.0
Elution: 5 ml Acetone/gl
Authors: SPE Department
Source: Macherey-Nagel